Quantcast
Channel: Bentley Communities
Viewing all articles
Browse latest Browse all 289

What's new and changed in LEAP Bridge Enterprise V8i (SELECTseries 7) v14.00.00.19

$
0
0

LEAP Bridge Enterprise V8i (SELECTseries 7) v14.00.00.19 ReadMe


Version

V8i v14.00.00.19 (SELECTseries 7)

Operating
Systems

Windows 7

Language

English


Before you begin, please note the following:

    • Review the End-User License Agreement (or EULA) carefully during the installation of LEAP Bridge. By installing this release, you agree to the terms and conditions of the agreement. A copy of the End User License Agreement named EULA.pdf will be included in the "\LEAP Bridge Enterprise\eula.pdf" folder of the product installation. By default, this location is "C:\Program Files\Bentley\LEAP Bridge Enterprise."
    • Before installing LEAP Bridge, be sure to fully read this document as well as the Installer Note where you can find critical information important to your installation.

This document contains the following information:


What is New & Changed?


CONTENTS

  • LEAP Bridge v14.00.00.19

  • LEAP CONSPAN v14.00.00.19

  • LEAP CONBOX v14.00.00.19

  • LEAP RC-PIER v14.00.00.19

  • LEAP GEOMATH v14.00.00.19

  • Upgrade Instructions

LEAP Bridge Enterprise V8i (SELECTseries 7) v14.00.00.19 incorporates the following enhancements and fixes to itself and its component programs:

LEAP Bridge v14.00.00.19

Enhancements:

  • A new option to specify minimum beam seat depth for all bearings on a support is now available

  • For skewed abutments and piers, user can now select an option which will draw edges parallel to deck in the 3D model and 2D views.

  • A new report showing top of cap elevations (for supports on either side of span) has been added.

  • A new option to export 3D model as solids instead of meshes on the export to DGN option has been implemented.

  • In order to improve the workflow when starting with ABC Wizard, the File>Save option in the component programs is now disabled. By simply closing the component program, data is saved back to LEAP Bridge model. In the preferences user can chose an option to have the program display a message with options to send/not send back to the main bridge model.

     

Fixes:

  • Input restrictions on minimum width and height of back-wall on abutments have been removed.

  • Barrier concrete quantities in the report were incorrect for some cases. Fixed now.

  • By default, the export of 3D model to DGN now uses Survey Foot and Survey Inches.

  • On export to DGN, H-piles now show correct EC data properties.

  • Some data flow corrections to support multiple bridges in a single file have been implemented.

  • A program crash due to missing pile patterns in library was fixed.

     

LEAP CONSPAN v14.00.00.19

Enhancements:

  • 2013 Interim Revisions to the LRFD Bridge Design Specifications are now implemented. The primary change is phi factors based on strain limits rather than c/dt ratios and support for high strength steel.

  • A new option has been added to neglect the haunch contribution to section properties computation is now available. Program will only consider the self-weight only in this case.

  • Connection to AASHTOWare Bridge Design/Rating (formerly Opis/Virtis) is now updated to support v6.5.

     

     

Fixes:

  • Fixed program crash when working with layout of non-voided rectangular slabs

  • For flared girder geometry cases, if beams were detected to be laid out non-continuously, program prevented analysis from being run. Now only the warning is shown, but user can still run analysis.

  • Some users reported program crashes when generating Enhanced Report for Positive Envelope Stresses. Fixed now.

  • Positive Envelope Stress graph corrected to show the correct Limiting Stress for Service I limit state.

  • For Canada code, the dead load factors were printed as zero’s in the rating reports. Did not affect final results. Now fixed. Also some minor differences between summary report and detailed rating report were corrected.

     

     

LEAP CONBOX v14.00.00.19

Enhancements:

  • Limit State Design for India

  • LRFD Interims 2013

  • An option to include or exclude the secondary moment in cracking moment calculations

  • Improved analysis reports of truck/lane, live load, service/strength limit states, and substructure reactions with more clarity

  • Improved detailed bending design report for strain compatibility option

  • Added warning message when the anchor set length overlaps

     

Fixes:

  • Self weight of columns incorrectly added to bottom-of-column reactions in various dead loads (including barrier, sidewalk, railing)

  • The option “Use Single Lane DF” did not work for Tee bridge

  • Incorrect moment diagram of Strength I

  • Discrepancy in reactions to the self weight between different versions

  • Discrepancy in column height between the printout report and the definition in the model

  • Incorrect calculation of the cracking moment for California option

  • Incorrect calculation of the factored moment capacity per Canadian code

  • Incorrect report of PT internal forces at the Initial stage

  • Self weight of columns incorrectly subtracted from substructure reactions for load combinations

  • Column length in the design report did not match the input in the model

  • Double trucks and tandems were not considered in substructure reactions

  • Incorrect calculation of negative moment capacity in Tee bridge

     

Note:

In CONBOX v12.01.00.57 the modeling assumption for tendons crossing variable depth cross-sections was modified. The change was made to produce zero Vp for straight horizontal tendons. This change typically resulted in slightly higher required PJack force. However, it is realized that a straight horizontal tendon crossing variable depth cross-sections would indeed produce Vp, since the tendon axis would not be parallel to the sloping CG axis. V14.00.00.xx rolled back the change introduced in V12.01.00.57

 

LEAP RC-PIER v14.00.00.19

 

Enhancements for US, Canada, and India:

  • Limit State Design for India
  • LRFD Interims 2013
  • Rigid Links in pier caps over columns
  • Overturning check on longitudinal moment for substructure
  • Option to auto-design pier cap using a uniform steel configuration
  • Improved RCP algorithm to optimize memory using for huge number of load combinations and handle zero length members
  • Auto-generation of load combinations with wind loads for Canadian code

 

Following issues were fixed for US, Canada, and India:

  • Non-Tapered Segment was not allowed to be less than two-third the total Cap length
  • The stem wall in 2D plan view did not match that in 3D view
  • Unable to export displacement and rotation results of all combinations to Excel
  • Incorrect volume calculations of cap and column for the Variable Cap Shape option
  • Incorrect wind loads for pier column with non-uniform section along the height
  • Start Elevation in the detailed design report did not match that of the model in the Stepped Cap pier
  • Incorrect wind loads on columns under multiple wind attacking angles
  • Incorrect self weight of the abutment when the option of Integral Abutment Bridge was toggled on
  • Incorrect effective steel area of the top reinforcement of footing
  • Incorrect load effects in combined footing when columns were eccentric to pile cap
  • Incorrect shear capacity in two-way shear check on footing
  • System was unstable while print the controlling combinations in the analysis results
  • Irrelevant symbols showed up in the pile reaction report
  • Incorrect update of structure model when Extreme Event Seismic Group was added
  • Loads at bearings were incorrectly applied above the ledge in Inverted Tee pier
  • Input values of bearings were incorrectly retained in the strut and tie model
  • Rounding of input values of steel reinforcement did not allow the design procedure to proceed in pier column design
  • Incorrect height of wall pier was used in auto-generation of loads
  • Incorrect load effect of transverse moment Mzz in isolated footings

 

Additional issues fixed for US:

  • SERVICE III group was missing when the option “WS as per FDOT SDG 2.4” is checked
  • Incorrect distributed out-of-plane forces in columns for California design option
  • Flexural design report showed incorrect tension/compression control for California option
  • Incorrect implementation of Response Modification Factors for seismic load auto generation
  • Incorrect axial loads and moments imported from CONBOX to RC-PIER
  • Design footing for magnified moments did not work
  • Effective area of reinforcing steel was incorrectly calculated at ends of cap when 180 hook bars were specified
  • Incorrect minimum required steel in the column design
  • Incorrect note showed up when there was no red flag in the report
  • Incorrect height was used to generate lateral soil pressure in abutment for the option "Piles integral with cap"
  • Load effects of transverse forces were incorrect calculated for the pressure loads WS and WA

 

Additional issues fixed for Canada:

  • Incorrect cracking/fatigue check for footing cap
  • Incorrect calculation of required steel reinforcement at bottom of pier cap of the hammer head pier
  • Incorrect calculation of shear capacity provided by concrete
  • Incorrect auto generation of wind load combinations per Canadian code
  • Incorrect load factors of braking load in the SLS
  • Incorrectly calculated load effect due to the lateral earth pressure
  • Incorrect height of columns was used to generate wind load on pier columns
  • Incorrect two-way shear capacity for footing cap
  • Ce factor for live load auto-generation per Canadian code did not work

 

Additional issues fixed for India:

  • Incorrect load effect due to braking load
  • Incorrect governing case was selected from the multiple live load types

Geometry Module: GEOMATH v14.00.00.19

 

Fixes:

  • Minor fixes to accommodate changes in LEAP Bridge


Upgrading from LEAP Bridge Enterprise

    • Follow the on-screen instructions and install the program.
    • The program will automatically be installed in the existing LEAP Bridge Enterprise folder.
    • During installation, program default libraries will be added under “C:\ProgramData\Bentley\LEAP Bridge Enterprise\” folder to comply with Windows standards to eliminate problems with access to users without Admin privileges.
    • The installation program will not overwrite the files already existing in the library folder.
    • If you have customized program libraries, you can move them to the above folder, and set the correct paths in the Library Setup dialog from within LEAP Bridge interface.

Installer Note

How to install & activate LEAP Bridge V8i (SELECTseries 7)?

Contents:

  Installation Wizard

  Activation wizard


This section guides you through the process of installing LEAP Bridge on your computer. In order to install LEAP Bridge V8i, please login as an Administrative user. LEAP Bridge can be installed by invoking Setup.exe. If you use Setup.exe, no other special consideration is necessary. Simply follow the instructions that follow. For details on the installation, please refer to the Installation Wizard section in this manual.

Note: LEAP Bridge V8i requires Microsoft .NET 4.0 framework to be installed in order to operate properly.

Installation Wizard:

    • First log into the Bentley SELECT Services Web site and download the LEAP Bridge installation kit for the version you have purchased. Please do not download the individual components (such as CONSPAN, RC-PIER, etc.) if you intend to install LEAP Bridge. The LEAP Bridge Enterprise installation package includes the necessary components.
    • Once you have downloaded the LEAP Bridge Enterprise installation files, locate the install folder. Run the installer file by double clicking the setup.exe icon.
    • You will be greeted by the Welcome screen. Click Next> to proceed with the installation process.
    • You are now presented with the End User License Agreement for this software. Please read the agreement and then click the radio button to accept the terms when finished. You may also print a copy for your records. Click Next> to continue.
    • You will be asked for an installation location. This is the directory location of the program on your computer.
    • The installer now has gather all the information needed to complete the installation. Click Install to finish the process. The wizard begins installing the program onto your computer. Once the process is complete, click Finish to exit the Wizard..
    • After the installer completes its process, the program is ready for use. You can launch the program by clicking the Start button and then All Programs > Bentley > LEAP Bridge Enterprise.

Note: Until you have activated a license for the program, it will remain in demo mode and function for only 30 days past installation.

Activating a product using the Product Activation Wizard

This is for installations which use a Bentley Server to authenticate the Bentley SELECT License used to run LEAP Bridge. In order to complete the installation, the SELECT Server Name and Site Activation Key will be required. If you do not have these, please contact Bentley technical support. Without this information the installation will operate using a trial license for only 30 days.

    • Install LEAP Bridge Enterprise following the instructions in the Installation section.
    • Locate the Bentley SELECT License Management Tool, LicenseTool.exe in the program installation folder (typically the location is c:\Program Files\Bentley\LEAP Bridge Enterprise\).
    • Select the SELECT subscriber activating against a hosted (Bentley) SELECT Server option and then click the Next > button.
    • The dialog box displays with the Server name provided for Bentley’s server. Complete the Site Activation Key received from Bentley and click the Next > button. Before accepting the entered information, you may also choose to click the Test Connection button to confirm that the entries are correct.
    • Enter the SELECT Server name and the Site Activation Key received from Bentley, and click the OK button. If you do not know these, please contact your system administration. Before accepting the entered information you may also choose to click the Test Connection button to confirm that the entries are correct.
    • After the information is accepted by the system, the program then displays all the available licenses for your usage as shown in the following dialog box. The license security is now in place. The installation is complete and LEAP Bridge is ready for use.

Note: You may need to contact your system administrator if your organization uses a proxy server to connect to the Internet. Click the Proxy... button in the Product Activation Wizard to display a dialog for entering these connection settings.


Directory Structure

The default directory of LEAP Bridge is "C:\Program Files\Bentley\LEAP Bridge Enterprise\", if the user has not changed the location during installation. The tutorials are installed in the Example directory within LEAP Bridge folder. Help directory within LEAP bridge folder contains all the necessary help files for individual components. Lib folder contains the default library files for rebars, tendons, cross sections. It is recommended not to delete the default library files. Starting with v12.01.00.57, there is a change in the location of the library files. During installation, program libraries will by default be added under “C:\ProgramData\Bentley\LEAP Bridge Enterprise\” folder to comply with Windows standards to eliminate problems with access to users without Admin privileges. If you have customized program libraries, you can move them to the above folder, and set the correct paths in the Library Setup dialog from within LEAP Bridge interface.


Support and Services Information

FAQs, What's New/Changed and other technical information can be found on Bentley's technical support documentation page.

You can efficiently log issues that you encounter in Bentley products with the Service Ticket Manager. Information on other professional support and service offerings from Bentley is available online at SELECTservices Online.


Using the Online Help

LEAP Bridge features a user manual available in the .chm format. A pdf version of the step by step guide to the tutorials is also provided. Tutorial files are located in Example directory. Adobe® Acrobat Reader® is required to use the pdf tutorial manual. Acrobat Reader is a free download available at www.adobe.com. The installation process will automatically install the user manual for LEAP Bridge and each component application (GEOMATH®, CONBOX®, CONSPAN® and RC-PIER®) in the Help folder. To access the manual and tutorials, select the appropriate link from the Help menu.


Last updated 2014/10/22 14:00:00
 
© 2014 Bentley Systems, Incorporated. Legal Notice

 